Fresenius Kabi Ivenix Infusion System LVP Software
The Ivenix Infusion System LVP Software has instructions for LVP duration programming that are emphasized in the IFU.
HANGZHOU BEVER MEDICAL DEVICES BD Ready-to-Use Hydrophilic Catheter
The BD Ready-to-Use Hydrophilic Catheter has a labeling error with an incorrect expiration date.
Medline Kits With B. Braun IV Administration Sets
Medline kits containing B. Braun IV administration sets may have check valves that stick.
12 productsMedicrea IB3D Universal Implant Inserter and PL Instruments Set
Medicrea IB3D Universal Implant Inserter and PL Instruments Set may have a handle that untreads, causing inability to rotate implant.
2 productsMedtronic Neuromodulation Vanta Clinician Programmer Application
The A71200 Vanta Clinician Programmer Application does not function as intended during use, potentially causing a prolonged or postponed surgical procedure.
Mobius Imaging AIRO Computed Tomography X-Ray System Pendants
AIRO pendant replacement kits and upgrade do not possess the "Safe Hand Position Warning" label.
2 productsGE Medical Systems Israel Emission Computed Tomography Systems
Certain Nuclear Medicine systems could have been transported without adequate detector support, potentially causing a detector fall and life-threatening injury.
4 productsBoston Scientific Coyote Over-the-Wire PTA Balloon Dilation Catheters
The Coyote balloon catheter may not inflate or deflate properly during use.
BD Pyxis ES Enterprise Server
The BD Pyxis ES Enterprise Server has a software issue that may result in equipment not receiving timely updates.
Remote Diagnostic Technologies Philips Tempus Pro Patient Monitor and USB 2-Channel IBP Module
The Philips Tempus Pro Patient Monitor measures intracranial and bladder pressure, but these measurements have not been tested for accuracy.
Sophysa Pressio 2 ICP Monitoring System
The Pressio 2 ICP Monitoring System can reboot, causing customer complaints.
Abiomed Impella 5.5 with SmartAssist S2
The Impella 5.5 with SmartAssist S2 Set is packaged in an incorrect outer box carton.
Integra LifeSciences Codman Microsensor and CereLink ICP Sensor Basic Kits
The Codman Microsensor Basic Kit may have corrosion stains on its included needle.
2 productsSecuritas Arial 900 MHz Call Stations
Arial 900 MHz Call Stations may fail to transmit a low battery alert before battery failure.
2 productsMedline Hudson RCI Medium Concentration Oxygen Masks
Oxygen masks have tubing that can disconnect, which may delay patient care and cause shortness of breath leading to hypoxia.
IMRIS HFD100 Head Fixation Device
The Head Fixation Device HFD100 has a torque screw that may crack or separate, risking patient injury.
Philips Smart-Hopping 2.0 AP 1.4 GHz Patient Monitor
The MX40 device could not reconnect when moving between Radiohead and Trident 1.4 GHz access points if the signal strength changed quickly.
Siemens LUMINOS Lotus Max and Luminos dRF Max
Luminos Lotus Max and Luminos dRF Max systems may have incorrect collimation when switching quickly between organ programs.
Philips Incisive CT
Philips Incisive CT may have an incomplete scan due to an unstable connection inside the floating sensor.
Vision RT AlignRT InBore System
The AlignRT InBore system has an omission in its Instructions for Use regarding laser information.
Beckman Coulter UniCel DxI 600 and DxI 800 Immunoassay Systems
Beckman Coulter UniCel Dxl 600 and UniCel Dxl 800 analyzers may not restart after a standard shutdown, causing delayed results.
2 productsMeridian Bioscience Revogene C. Difficile Assay
The Revogene C. difficile assay may give false-negative results due to declining performance over time.
Halyard Organ Recovery OR Pack and Mini Plus Kit South
Halyard Organ Recovery OR Pack and Halyard Mini Plus Kit South are not suitable for organ transplant.
3 productsRoche Diagnostics Elecsys Anti-TSHR Immunoassay
The Elecsys Anti-TSHR immunoassay gives results that vary by platform and calibrator lot, which may lead to delayed or incorrect diagnosis and treatment.
Applied Medical Kii Low Profile Bladed Dual Pack
Kii Low Profile, Bladed Dual Pack has a potential for extended blade obturator length after assembly.
Abbott Diabetes Care FreeStyle Libre 3 and FreeStyle Libre 3 Plus Sensors
Abbott Diabetes Care sensors may give incorrect low glucose readings due to a manufacturing issue.