Beckman Coulter MicroScan Neg MIC 56 Panels
MicroScan panels may be contaminated in some wells.
Datascope Battery Charging Station
The Battery Charging Station has a protruding screw that prevents proper charging of certain batteries.
Leksell Gamma Knife
The Leksell Gamma Knife has an adapter that may not be properly aligned or locked in place.
ConvaTec EsteemBody Drainable Pouches
Convatec EsteemBody Drainable Pouch may leak due to a manufacturing issue.
3 productsAptima HPV Assay
The Aptima HPV Assay can generate invalid or false negative results.
Stryker Cub Pediatric Crib
The Cub Pediatric Crib is missing two access door warning labels.
STA Liatest D-Di
After receiving customer complaints, investigations confirmed the presence of a positive bias in D-Dimer measurements throughout the entire analytical range.
Howmedica Osteonics MICS3 Angled Sagittal Saw Attachment
The MICS3 Angled Sagittal Saw Attachment has screws that may loosen and detach during use.
Centricity Universal Viewer Software
Centricity Universal Viewer Software has a cybersecurity vulnerability that may expose user login credentials.
3 productsAbbott Diagnostics Scarborough ID NOW Influenza A & B 2
The ID NOW Influenza A & B 2 has a higher occurrence of invalid rates.
Insulet Omnipod 5 Pods
Omnipod 5 Pods may have a tear causing insulin to leak inside, leading to under-delivery or cessation of insulin.
Medline Medcrest Surgical Gowns and Surgical Drapes
Medline Medcrest Surgical Gowns may experience premature delamination, which can cause brief delays in patient care and risk of infection.
2 productsLutronic CLARITY II Laser System
The Clarity II Laser System can spark or pop and potentially burn patients.
Altruan Strep A At-Home Self-Tests
Altruan GmbH is recalling its Wondfo Streptococcal A At-Home Self-Test, Clearest Strep-A Cassette Test, and Bisaf Strep A Self-Test because of product not cleared by the FDA.
3 productsInternational Life Sciences Artelon FlexBand Dynamic Matrix and FlexBand Plus
Artelon FlexBand devices failed bacterial endotoxin testing.
3 productsBeckman Coulter Chemistry Analyzers AU5800 and DxC 700 AU
Beckman Coulter Mishima K.K is recalling its Chemistry Analyzer Au5800 and DxC 700 Au because A delay in results may occur.
2 productsHealthCast "Vital Sync" Remote Patient Monitoring System
Alarms from the primary patient bedside monitor may not be transmitted or received on the remote system.
EndoVive Safety PEG Kit
The EndoVive Safety PEG Kit contains ChloraPrep Triple Swabsticks with open or compromised seals.
GEM Premier 5000
GEM Premier 5000 PAK may experience increased Process Control Solution Not Detected errors during warm-up, causing ejection and delays.
20 productsPhysio-Control Infant/Child Reduced Energy Defibrillation Electrodes
Infant/Child Reduced Energy Defibrillator Electrodes may delaminate, which can affect defibrillation.
Penner Pacific Bathing Spas
The Penner Pacific Bathing Spa lacks a unique device identifier.
10 productsRaz Mobile Shower Commode Chairs
Mobile shower commode chairs may be reinstalled without properly engaging the outside rear seat brackets that keep the seat in place.
Vascutek Gelsoft Plus and Gelweave Vascular Grafts
Gelatin sealed woven polyester prostheses devices, designed for vascular repair, were incorrectly labeled with an additional month of shelf life.
Olympus Single Use Biopsy Valve
The Olympus Single use Biopsy Valve can detach rubber fragments during use.
2 productsDatascope CS100 and CS300 Intra-Aortic Balloon Pumps
The CS100 Iabp and CS300 Iabp have battery runtime and cycle specifications that need to be updated.
2 productsSTA Liatest Free Protein S
The STA Liatest Free Protein S kit may show out-of-range results and underestimate free protein S levels in normal plasma.
Esaote Endocavity Ultrasonic Probe E 3-12
The Esaote Endocavity ultrasonic probe may leak liquid from its casing near the cable.
Aesculap MINOP Trocar
The Minop Trocar 150MM 4 Wking CHANNEL6.0MM may have a trocar shaft that is too long.
Atellica CH Urine Albumin (UAlb)
Atellica CH Urine Albumin may report falsely depressed results for samples above 40.0 mg/dL.
Impella RP
The Impella RP devices have a sensor that may malfunction, causing sensor values to drift.
3 productsCobas Pro Integrated Solutions with Cobas C 503 analytical Units
The cobas pro integrated solutions with cobas c 503 analytical units have a software defect that can cause erroneous patient results.
GE Healthcare Centricity Universal Viewer Zero Footprint Client
The viewer may show patient information that does not match the images displayed.
Olympus ShockPulse-SE Lithotripsy System Reusable Probes, Single Use Probes and Generator
The ShockPulse-SE Lithotripsy System can remain in a blinking phase waiting to recognize the transducer due to damage to the plug or receptacle.
3 productsMedtronic Octopus Nuvo Tissue Stabilizer
The Octopus Nuvo Tissue Stabilizer has tubing incorrectly positioned, which may cause assembly issues.
Agiliti Adapt Pump
The Adapt Pump may not re-engage the Microclimate Management function after using Autofirm for 10 minutes.
Medline Kits with Tego Connectors
Medline kits containing Tego Connectors may have silicone seal issues that can cause fluid leakage or air infusion.
6 productsMedline Sterile Saline Wound Wash and Convenience Kits
Medline Sterile Saline Wound Wash may not meet sterility requirements.
5 productsMRIMed MRI LED Mobile Exam Light Battery
Due to battery component overheating while charging resulting in melting of internal components and causing smoke.
Olympus Resection and Inner Sheaths
Olympus Resection and Inner Sheaths have a ceramic tip that may break.
20 productsOlympus Cystoscope Outer Sheath
The Olympus Cystoscope Outer Sheath is being removed due to incompatibility with a GreenLight Laser that could damage the device tip.
Olympus High Flow Insufflation Unit
The Olympus High Flow Insufflation Unit has a software issue that may lead to overpressure events.
3 productsMedline Convenience Kits and Surgical Drapes
Medline Convenience Kits and Surgical Drapes may not be sterile due to calibration issues in sterilization equipment.
42 productsAuris Health MONARCH Bronchoscopy Platform
Monarch Platform, Bronchoscopy has a software issue that may cause unanticipated robotic arm positioning.
Stryker MOLLI 2 System, Introducers, Wand, OncoPen and Tablet
The Molli 2 System needs updated labeling because magnetized surgical tools can dislodge markers during tissue removal.
Olympus Thunderbeat Surgical Devices
Firm is initiating a removal due to continued reports of adverse events.
12 productsWilson-Cook Teslatome Bipolar Sphincterotomes
Teslatome Bipolar Sphincterotomes may have a void in material separating wire guide and cutting wire lumens, causing inappropriate current path during cutting.
Immunotech Estrone RIA
Estrone RIA may rarely give falsely high patient results, which might cause temporary injury.
Bard Broviac Single-Lumen CV Catheter Cutdown Tray
The Broviac catheter tray has damage to its outer tray that can compromise the sterile barrier.
Medline IV Administration and Extension Sets
IV administration and extension sets may leak, crack, or break, causing treatment delays, blood loss, infection, air embolism, or underdosage.