Medical device recalls
Kico Knee Innovation Arvis Surgical Navigation System GEN 2
The ARVIS surgical navigation system may show a tilted image due to an internal sensor issue.
Philips Cardiac Workstation 5000 and 7000
The Cardiac Workstation 5000 may provide inaccurate heart rate data.
2 productsDentsply Sirona Capsule Mixer
The Dentsply Sirona Capsule Mixer can discharge electricity when unplugged.
EndoFLIP System
The EndoFLIP System can incorrectly flag catheters as expired, making them unavailable for clinical procedures.
Cardinal Health Presource Kits
Procedure kits contain neurological sponges with unexpected variability in endotoxin levels.
8 productsErbe USA ERBECRYO 2 Cryosurgical Unit
The ERBECRYO 2 Cryosurgical Unit can rupture its cryoprobe due to excessive pressure from a strong pull on the hose.
Straumann Bone Level Tapered (BLT) Implant
The Straumann Bone Level Tapered Implant may contain implants that are 12mm instead of 14mm.
Baxter Duo-Vent Solution Set and Male Luer Lock Adapter
The Baxter Duo-Vent Solution Set and Male Luer Lock Adapter can have air bubbles in the drip chamber and tubing.
OBP Medical ER-Spec Single-Use Vaginal Speculum with LED Light Source
The ER-Spec vaginal speculum may have a burr on the blade, introducing a sharp edge for patients and providers.
Philips Allura Xper FD Interventional Fluoroscopic X-Ray Systems
Allura Xper FD has a firmware issue that could lead to loss of geometry movements.
Terumo Glidesheath Slender A-Kit
The Glidesheath Slender was packaged with the 0.025 guidewire instead of the 0.021 guidewire.
Thermo Fisher Diagnostics Neisseria Meningitidis Gp C Tests
Neisseria meningitidis Gp C 2ml/VL is not performing to IFU criteria, not positive to ATCC13102 within 60 seconds.
Medline Micro-Kill Bleach Germicidal Bleach Wipes
Medline Micro-Kill Bleach Germicidal Bleach Wipes may have reduced bleach concentration before the end of their shelf life.
4 productsCovidien V-Loc, Dermalon and Surgipro Wound Closure Devices
V-Loc 90 Absorbable Wound Closure Device may have a perforation or tear in its sterile barrier packaging, which may lead to infection or prolonged surgery.
5 productsXhibit Central Station
The Xhibit Central Station has audio/video failures due to a display port component.
GORE VIABIL Short Wire Biliary Endoprosthesis
The GORE VIABIL biliary endoprosthesis may be mislabeled, with a 10 mm x 7 cm device labeled as a 10 mm x 10 cm device.
2 productsMedline Hudson RCI Heated Neonatal Breathing Circuits
Neonatal and infant heated wire breathing circuits may experience sporadic failure.
3 productsSiemens Healthcare Diagnostics Atellica CH Urine Albumin
Atellica CH Urine Albumin tests may cause falsely depressed urea nitrogen and hemoglobin A1c results.
Philips Allura and Azurion X-Ray Systems
Potential Loss of imaging functionality, loss of motorized movement, or loss of data due to unauthorized Hard Disk Drives.
3 productsFilmArray NGDS Warrior Panel
The FilmArray NGDS Warrior Panel has mismatches between the outbreak strain and the reference strain used in its development.
GE Healthcare MAC VU360 Electrocardiographs
After selecting the order refresh icon, an open preview or review screen might fail to close automatically after 2 minutes of inactivity.
Merge OrthoPACS and PACS
Merge PACS may show thumbnails from a previous patient study while another is open.
2 productsSyva Emit Tox Serum Tricyclic Antidepressant Calibrator/Controls
Syva Emit tox Serum Tricyclic Antidepressant Calibrator/Controls have out-of-specification sodium azide concentration, causing low health risk.
Happiest Baby Pre-Loved SNOO Smart Sleeper
The pre-loved SNOO Smart Sleeper failed to meet quality standards before distribution.
Stryker Ahto Tube Sets and Suction/Irrigator Packaging
Stryker tube sets can leak from the handpiece during use.
5 productsFORWARD Oral Airway Kit and Kingfisher Compact Individual First Aid Kit
The FORWARD Oral Airway Kit may have an occluded or partially occluded Guedel Airway tip.
2 productsQuantum Rehab Power Wheelchairs
Quantum Rehab powered wheelchairs may show reminder pop-ups while in use, which can cause an unexpected park brake stop and lead to a fall or injury.
13 productsCharger for the Therabody Theragun, G4 PRO Massage Device
The charger for the Theragun G4 PRO may overheat, posing a fire risk.
Terex Utilities Power Over Fiber Base Module
The Power Over Fiber Base Module is not certified and is improperly labeled.
Stryker Hoffmann II Connecting Rod Micro
Stryker Hoffmann II Connecting Rod Micro may crack following cleaning and sterilization.
7 productsInstrumentation Laboratory GEM Premier 5000 and GEM Premier 7000 Blood Analyzers
GEM Premier 5000 and 7000 systems with BCR wands may assign results to wrong patient.
6 productsResMed Astral 100 and 150 Ventilators
The Resmed Astral ventilator system can fail due to electrolyte leakage, interrupting ventilation therapy.
Philips CT Scanners
The CT scan may not trigger automatically after Bolus Tracking, causing inadequate diagnosis and potential rescan.
3 productsMedtronic EOPA Arterial Cannulas
Pinhole leaks may occur in the wire-wound body during cardiopulmonary bypass.
6 productsMiniMed Go App
The MiniMed Go App may miss nighttime alerts, leading to missed insulin doses and increased hyperglycemia risk.
Olympus High Flow Insufflation Unit - UHI-4
The Olympus High Flow Insufflation Unit can have its front panel display turn off unexpectedly, and air delivery ceases.
Penumbra System RED 68 Reperfusion Catheter
The Penumbra System RED 68 Reperfusion Catheter may fracture due to manufacturing issues.
Boston Scientific FARADRIVE Steerable Sheath Clear
The FARADRIVE Steerable Sheath Clear can have valve damage that may cause air ingress and potential air embolism.
4 productsHotline Fluid Warming Set
The Hotline Fluid Warming Set may have an increased likelihood of leakage in specific lots.
Paragon 28 Phantom Hindfoot TTC/TC Ball Tipped Guide Rod
The P28 Phantom Intramedullary Nail System guide rod has breaches in its sterile barrier.
Tosoh ST AIA-Pack Testosterone Test
The test cup lot F level 1 low-quality control results were lower than expected, which could cause falsely elevated or falsely low total testosterone results.
Daavlin Photera Phototherapy Devices
The Photera 400 phototherapy device has incorrect UV sensor gain.
3 productsPapablic Replacement Brush Heads
Papablic Replacement Brush Heads have a potential to break.
2 products3B Medical Rio II Nasal Pillows Interface
The Rio" II Nasal Pillows Interface has a packaging and labeling discrepancy involving product size identification and associated UDI.
GE Optima XR200amx, XR220amx and XR240amx Radiographic Systems
This could result in patient injury during an exam.
3 productsBoston Scientific Rapid Refill Continuous Injection System
The Rapid Refill Continuous Injection System contains a syringe that may loosen or disconnect, causing fluid leakage or separation.
ICU Medical Plum Duo Infusion and Solo Precision IV Pump
The Plum Duo Infusion Pump may deliver up to twice the programmed volume in a specific scenario.
2 productsArgon Medical Devices Cardiovascular and Biopsy Trays
Transvenous Pacing Electrode Tray w/ Bipolar Balloon Pacing Electrode 5F may not meet sterility release criteria.
6 productsAbiomed Impella Heart Pumps and Introducer Kits
A potential for introducer sheath leakage from under the sheath cap and along the hub score lines, identified in 14Fr and 23Fr Introducers.
13 productsOlympus Evacuators
Some sterilization parameters may not consistently render the devices adequately sterile.
4 products